Bomba RS II and reg; VSTD
Highlights:
Energy saving and efficiency: up to and eacute; 75% savings and flexibility in electrical and electrical energy consumption.
Great acoustic and water comfort when operating at low speeds.
Simple and intuitive digital interface.
4 digital inputs to allow controlling the pump via an external controller.
Rotating box at 180°, for practical and acute access; user interface.
New alloy box and ccedil; and otilde;es that facilitates the connection and ccedil; and atilde;o eacute;trica.
Quarter-turn opening lid for easy and easy maintenance; and atilde;o.
Unions and otilde;es of connections and ccedil; and installation provided, thus guaranteeing an easy installation; and simple attitude.
Poupan and ccedil;a Energ and eacute;tica
Engine Speed
The bigger and eacute; the frequency (Hz), higher and eacute; the route speed and ccedil; and engine speed (rpm). In 2-pole motors, the route is accessible; and atilde;o and eacute; approximately [frequ and ecirc;ncia x 60]:
- 30 Hz ~ 1800 rpm
- 40 Hz ~ 2400 rpm
- 50 Hz ~ 3000 rpm
The flow rate and eacute; proportional and aggravated; speed
The pressure and atilde;o and eacute; proportional to the square of the speed
The power and ecirc;nce and eacute; proportional to the cube of speed
For example, if we reduce the speed by 30%, the new parameters will be as follows:
Flow ~ 70% of the original
Head and head height ~ 49% of original
Power and ecirc;nce ~ 34% of original