OLIJU Vortex N Submersible Pump
Submersible pumps with vertical outlet for drainage and wastewater containing soft solids. The vortex impeller allows solids to pass through, depending on the model.
Choose the model, power supply and version with or without float in the selector.
- ✔ Water up to 35 °C.
- ✔ Maximum immersion depth: 10 m.
- ✔ H07RN-F neoprene power cable, 10 m long.
- ✔ Motor with IP68 protection and class F insulation.
- ✔ Pump body made of cast iron and motor casing made of stainless steel.
💧 Head ( m ) by flow rate ( m³/h )
| m³/h | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | 0 | 1,5 | 3 | 4,5 | 6 | 7,5 | 10,5 | 12 | 15 | 18 | 21 | 24 | 27 | 30 |
| N 40.15 | 7 | 6,3 | 5,5 | 4,7 | 3,9 | 3 | 1,1 | - | - | - | - | - | - | - |
| N 35.60 | 11 | 10 | 8,8 | 7,6 | 6,5 | 5,3 | 3,2 | 2,2 | 0,2 | - | - | - | - | - |
| N 40.75 | 11 | 10,2 | 9,5 | 8,8 | 8 | 7,2 | 5,4 | 4,5 | 2,5 | 0,4 | - | - | - | - |
| N 50.110 | 12 | 11,9 | 11,2 | 10,5 | 9,8 | 9,1 | 7,7 | 6,9 | 5,5 | 4,1 | 2,6 | 1,1 | - | - |
| N 50.150 | 14 | 13,6 | 12,9 | 12,1 | 11,3 | 10,6 | 9,1 | 8,4 | 7 | 5,6 | 4,2 | 2,9 | 1,5 | 0,3 |
Head in meters. Values from the official OLIJU technical data sheet at 50 Hz. The "-" sign indicates a value not provided in the manufacturer's table.
Model data
| Model | V | Float switch | kW | CV | Outlet (in.) | Max. H (m) | Max. Q (m³/h) |
|---|---|---|---|---|---|---|---|
| N 40.15.1M | 1x230V | No | 0,15 | 0,2 | 1 1/2 | 7 | 10,6 |
| N 35.60.1M | 1x230V | No | 0,6 | 0,8 | 1 1/4 | 11 | 15 |
| N 35.60.3 | 3x400V | No | 0,6 | 0,8 | 1 1/4 | 11 | 15 |
| N 35.60.1A | 1x230V | Yes | 0,6 | 0,8 | 1 1/4 | 11 | 15 |
| N 40.75.1M | 1x230V | No | 0,75 | 1 | 1 1/2 | 11 | 18 |
| N 40.75.3 | 3x400V | No | 0,75 | 1 | 1 1/2 | 11 | 18 |
| N 40.75.1A | 1x230V | Yes | 0,75 | 1 | 1 1/2 | 11 | 18 |
| N 50.110.1M | 1x230V | No | 1,1 | 1,5 | 2 | 12 | 26 |
| N 50.110.3 | 3x400V | No | 1,1 | 1,5 | 2 | 12 | 26 |
| N 50.110.1A | 1x230V | Yes | 1,1 | 1,5 | 2 | 12 | 26 |
| N 50.150.1M | 1x230V | No | 1,5 | 2 | 2 | 14 | 30 |
| N 50.150.3 | 3x400V | No | 1,5 | 2 | 2 | 14 | 30 |
Maximum flow rate and head values correspond to different points on the curve. Consult the technical data sheet to select the operating point.
The photo represents the series. Whether a float switch is included depends on the selected version.